The Mogilev Control and Analytical Laboratory renders services to legal entities on quality control of medicines and pharmaceutical substances registered in the Republic of Belarus prior to receipt for sale, as well as medicines that are in circulation on the territory of the Republic of Belarus.
APPROVED BY
order of the CEO
Mogilev trade and production
republican unitary
enterprise "Pharmacy"
dated December 23, 2016 No. 396-P
for the services of quality control of medicines of the Mogilev Control and Analytical Laboratory
№ п/п | Name of service |
Unit of measurement |
Retail price without VAT (tariff) rub. (administrative procedure) | Retail price without VAT (tariff) rub. |
1. | Weighing on pharmaceutical scales | one weighing | 0,39 | 0,43 |
2. | Weighing on torsion fiber balance | one weighing | 0,59 | 0,65 |
3. | Weighing on analytical balance | one weighing | 0,78 | 0,86 |
4. | Dissolution of the weighing in a volumetric flask | study | 1,17 | 1,29 |
5. | Extraction of the substance with an organic solvent | study | 4,49 | 4,95 |
6. | Distillation of organic solvent | study | 3,12 | 3,44 |
7. | Drying of substances to constant weight | study | 8,97 | 9,89 |
8. | Ignition and weighing the residue | study | 24,38 | 26,88 |
9. | Determination of ash insoluble in hydrochloric acid | study | 54,21 | 59,77 |
10. | Determination of sulphated ash | study | 25,74 | 28,38 |
11. | Measurement of the solution with a burette (pipette), a cylinder | one metering | 0,39 | 0,43 |
12. | Subsidence | study | 5,85 | 6,45 |
13. | Sludge washing | study | 12,09 | 13,33 |
14. | Qualitative determination of one ingredient without its extraction (chemical method) | study | 0,78 | 0,86 |
15. | Qualitative definition of one ingredient with its extraction (chemical method) | study | 1,17 | 1,29 |
16. | Quality control of medicinal product manufactured in pharmacies | study | 8,00 | 8,82 |
17. | Centrifugation of solutions | study | 4,10 | 4,52 |
18. | Determination of physical quantities in tablets, capsules, briquettes and other dosage forms using calipers | study | 5,85 | 6,45 |
19. | Measuring of length and width with ruler | study | 2,93 | 3,23 |
20. | Shaking | study | 2,93 | 3,23 |
21. | Determination of melting points up to 100°С | study | 7,02 | 7,74 |
22. | Determination of melting points above 100°C | study | 11,70 | 12,90 |
23. | Determination of boiling points | study | 4,49 | 4,95 |
24. | Fractional distillation up to 100°С | study | 9,95 | 10,97 |
25. | Fractional distillation above 100°C | study | 13,46 | 14,84 |
26. | Determination of viscosity | study | 9,95 | 10,97 |
27. | Determination of the rotation angle of the polarization plane | study | 8,78 | 9,68 |
28. | Determination of the angle of refraction | study | 1,95 | 2,15 |
29. | Microscopy in chemical analysis | study | 4,10 | 4,52 |
30. | Microscopy in the analysis of medicinal plant material | study | 8,19 | 9,03 |
31. | Microscopy in the determination of particles in ointments, suspensions and other dosage forms | study | 12,29 | 13,55 |
32. | Disintegration of tablets, briquettes, granules | study | 2,93 | 3,23 |
33. | Disintegration of coated tablets and capsules | study | 23,99 | 26,45 |
34. | Dissolution of tablets and capsules | study | 4,10 | 4,52 |
35. | Tablet abrasion | study | 4,88 | 5,38 |
36. | Hardness of tablets | study | 4,88 | 5,38 |
37. | Determination of pour points | study | 6,83 | 7,53 |
38. | Determination of the specific weight by Westphal (with areometer) | study | 3,12 | 3,44 |
39. | Determination of the specific gravity with a pycnometer | study | 6,83 | 7,53 |
40. | Purity test with a reference solution (water) | study | 2,93 | 3,23 |
41. | Determination of pH by indicator paper | study | 1,95 | 2,15 |
42. | Potentiometrical determination of pH | study | 4,10 | 4,52 |
43. | Viewing of 100 ampoules with injection solutions for mechanical inclusions | study | 8,19 | 9,03 |
44. | Acidimetric (coplesonometric) titration. Determination of acidity or alkalinity | study | 1,95 | 2,15 |
45. | Argentometric direct titration | study | 2,34 | 2,58 |
46. | Argentometric reverse titration | study | 3,12 | 3,44 |
47. | Iodometric direct titration | study | 1,56 | 1,72 |
48. | Iodometric reverse titration | study | 2,73 | 3,01 |
49. | Bromometric (iodochlorometric) titration | study | 6,83 | 7,53 |
50. | Permanganatometric (mercurimetric, cerimetric) titration | study | 7,61 | 8,39 |
51. | Diazotization (nitritometric titration), non-aqueous titration | study | 8,19 | 9,03 |
52. | Saponification | study | 4,49 | 4,95 |
53. | Oxidation | study | 4,49 | 4,95 |
54. | Recovery | study | 6,83 | 7,53 |
55. | Determination of the iodine number | study | 18,14 | 20,00 |
56. | Determination of saponification number | study | 13,46 | 14,84 |
57. | Determination of the acid number | study | 15,60 | 17,20 |
58. | Photocolorimetric determination | study | 6,83 | 7,53 |
59. | Nephelometric definition | study | 6,83 | 7,53 |
60. | Steam distillation | study | 8,78 | 9,68 |
61. | Acetylation | study | 8,78 | 9,68 |
62. | Determination of essential oil | study | 11,12 | 12,26 |
63. | Potentiometric titration | study | 14,04 | 15,48 |
64. | Determination of the volume of one ampoule | study | 0,78 | 0,86 |
65. | Determination of the volume of one vial | study | 0,39 | 0,43 |
66. | Determination of the mass of powder in the vial | study | 1,17 | 1,29 |
67. | Determination of the mass of ointments in the vial (tube), suspensions | study | 1,56 | 1,72 |
68. | Determination of the mass of the contents | study | 0,78 | 0,86 |
69. | Calculation of the quantitative content of one ingredient | study | 0,59 | 0,65 |
70. | Registration of the protocol | study | 1,95 | 2,15 |
71. | Determination of talc (aerosil) in tablets | study | 36,08 | 39,78 |
72. | Determination of talc (aerosil) in tablets containing non-combustible substances or substances insoluble in warm water | study | 65,52 | 72,24 |
73. | Determination of the deformation time of suppositories | study | 4,49 | 4,95 |
74. | Spectrophotometry (Authentication) | study | 9,95 | 10,97 |
75. | Spectrophotometry without a calibration curve (quantitative determination, determination of chromaticity) | study | 5,85 | 6,45 |
76. | Spectrophotometry, photoelectrocolorimetry (construction of a calibration curve) | study | 20,48 | 22,58 |
77. | Determination of nitrogen by Kjeldahl | study | 18,14 | 20,00 |
78. | Determination of alcohol by distillation | study | 22,04 | 24,30 |
79. | Determination of alcohol by boiling point | study | 11,12 | 12,26 |
80. | Commodity analysis of medicinal plant raw material (authenticity, crushing, content of impurities, degree of infection with granary pests) | study | 23,99 | 26,45 |
81. | Heating (boiling) | study | 4,10 | 4,52 |
82. | Cooling | study | 0,59 | 0,65 |
83. | Evaporation (volume of liquid up to 20 ml) | study | 12,09 | 13,33 |
84. | Evaporation (volume of liquid over 20 ml) | study | 19,89 | 21,93 |
85. | Trimming (grinding) | study | 0,39 | 0,43 |
86. | Determination of the average mass of tablets, capsules, briquettes, granules, packages | study | 0,78 | 0,86 |
87. | Determination of the deviations in the mass of individual tablets, capsules, briquettes, granules, packages (20 pieces) | study | 20,28 | 22,36 |
88. | Determination of solubility of substances in one solvent | study | 2,15 | 2,37 |
89. | Registration of all entries in the log | study | 7,80 | 8,60 |
90. | Filtration | study | 2,15 | 2,37 |
91. | Determination of organic impurities by chemical method | study | 2,15 | 2,37 |
92. | Determination of organic impurities by thin layer chromatography | study | 47,78 | 52,68 |
93. | Determination of authenticity by thin layer chromatography | study | 33,15 | 36,55 |
94. | Gas-liquid chromatography (quantitative determination, determination of impurities) | study | 112,32 | 123,84 |
95. | Gas-liquid chromatography (authentication) | study | 88,92 | 98,04 |
96. | Gas-liquid chromatography (determination of residual organic solvents) | study | 118,56 | 130,72 |
97. | Liquid chromatography (quantitation, determination of impurities) | study | 224,64 | 247,68 |
98. | Liquid chromatography (authentication) | study | 224,64 | 247,68 |
99. | Ignition | study | 3,12 | 3,44 |
100. | Determination of extractive substances | study | 34,52 | 38,06 |
101. | Determination of tannins | study | 40,17 | 44,29 |
102. | Test for arsenic | study | 40,17 | 44,29 |
103. | Definition of the essential value | study | 29,64 | 32,68 |
104. | Quality control of medicinal products in the sections "Description", "Packaging", "Marking" | study | 4,68 | 5,16 |
105. | Preparation and dispensing of reagents (1 bottle up to 100 ml) | study | 4,10 | 4,52 |
106. | Viewing of 10 vials of solutions for internal (external) use for the absence of mechanical inclusions | study | 0,98 | 1,08 |
107. | Determination of water by the Fisher method | study | 40,17 | 44,29 |
108. | Checking the packaging for leaks (for aerosols) | study | 4,10 | 4,52 |
109. | Determination of the peroxide value | study | 17,55 | 19,35 |
110. | Determination of arbutin | study | 62,60 | 69,02 |
111. | Combustion in a flask with oxygen | study | 5,27 | 5,81 |
112. | Registration of documents confirming the quality of medicinal products after quality control of medicinal products in accordance with the requirements of the Resolution of the Ministry of Health of the Republic of Belarus dated 01.03.2010 No. 20 (as amended on May 11, 2015 No. 68) | one drug | 2,34 | 2,58 |
113. | Execution of a photocopy of documents confirming the quality | one sheet (one-sided) | 0,78 | 0,86 |
114. | Sampling of medicinal products for testing within the location of the laboratory | application | 40,95 | 45,15 |
115. | Sampling of medicinal products for testing outside the location of the laboratory | application | 81,90 | 90,30 |
116. | Gravimetric method of quantitative determination | study | 29,25 | 32,25 |
117. | Filtration | study | 5,85 | 6,45 |
118. | Determination of nonvolatile substances | study | 13,26 | 14,62 |
119. | Specification | study | 1,76 | 1,94 |
120. | Identification of authenticity using IR spectrometry (using a crystal) | study | 24,57 | 27,09 |
121. | Identification of authenticity using IR spectrometry (using a bromine tablet) | study | 39,78 | 43,86 |
121-1 | Identification of authenticity using IR spectrometry (using a cuvette) | study | 34,91 | 38,49 |
121-2 | Assay of one ingredient by IR spectrometry | study | 49,73 | 54,83 |
122. | Determination of osmolality | study | 5,85 | 6,45 |
123. | Atomic absorption spectrometry | study | 44,85 | 49,45 |
124. | Determination of radionuclide activity | study | 26,33 | 29,03 |
125. | Determination of the electrical conductivity of water | study | 2,93 | 3,23 |
141 | Capillary electrophoresis (authentication) | study | 66,89 | 73,75 |
142 | Capillary electrophoresis (quantitative determination, determination of impurities) | study | 112,52 | 124,06 |
143 | Fluorimetry (definition of authenticity) | study | 12,87 | 14,19 |
144 | Fluorimetry (without calibration curve) | study | 7,02 | 7,74 |
145 | Fluorimetry (construction of a calibration curve) | study | 21,06 | 23,22 |
146 | Determination of water by the Fisher method (coulometric titration) | study | 37,05 | 40,85 |